Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37526950

RESUMO

In this study, a novel electrochemical aptamer sensor for detecting ochratoxin A (OTA) was constructed. First, a gold-copper alloy film was prepared via electrochemical deposition, and copper was selectively dissolved in constant potential mode for obtaining the nano-porous gold modified screen-printed carbon electrodes (NPG/SPCE). Then, 2-mercaptoethylamine was dropped on the NPG/SPCE surface and Au-S covalent bonds were formed for immobilizing the metal. Glutaraldehyde as cross-linking agent was added, which resulted in immobilization and attachment of PAMAM to the 2-mercaptoethylamine through the dehydration condensation reaction. During the preparation process, the nano-porous gold and PAMAM-modified layers were characterized by SEM, XRD, and IR spectroscopy, respectively. The characterization results showed that the nano-porous gold and PAMAM composite films were successfully modified. Finally, the OTA aptamer was cross-linked with PAMAM by glutaraldehyde to complete construction of the Apt/PAMAM/NPG/SPCE sensor. The electrochemical performance of this sensor was tested in ochratoxin A solutions with the DPV method. The results showed that the sensor's reproducibility, stability, and specificity were good. The spiked recoveries in red wine ranged from 99.65%∼101.6%, with a linear range of 0.5 ng/mL∼20 ng/mL and a minimum detection limit of 0.141 ng/mL. Thus, the novel biosensor may provide a promising tool for the trace detection of OTA.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Mercaptoetilaminas , Ocratoxinas , Vinho , Vinho/análise , Ouro/química , Cobre , Reprodutibilidade dos Testes , Glutaral , Limite de Detecção , Aptâmeros de Nucleotídeos/química , Ocratoxinas/análise , Técnicas Eletroquímicas/métodos , Eletrodos
2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-989166

RESUMO

Early hematoma enlargement is one of the main factors of early neurological deterioration in patients with intracerebral hemorrhage. The correlation between blood lipid and hematoma enlargement is a research hotspot at present. This article reviews the relationship between blood lipid and hematoma enlargement and outcomes in patients with intracerebral hemorrhage, as well as the correlation between statin treatment and hematoma enlargement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...